The Rigel Multi-Flo Infusion Pump Analyser is a high-precision, portable analyser designed to verify the performance of infusion pumps and syringe pumps in accordance with IEC 60601-2-24. Available in 1, 2 and 4-channel configurations, it delivers accurate flow, pressure, occlusion and bolus measurements while enabling simultaneous testing of multiple infusion devices to significantly improve testing efficiency.
Rigel Medical
In Stock
West Africa
24-Month Manufacturer Warranty (Registration Required)
Available in 1, 2 and 4-channel versions, allowing simultaneous testing of up to four infusion pumps, reducing testing time in high-volume biomedical environments.
Designed specifically to verify infusion devices according to IEC 60601-2-24, ensuring reliable performance and regulatory compliance.
Measures infusion flow rates from 0.010 to 1500 mL/h with exceptional accuracy, including low-flow applications commonly used in critical care and neonatal settings.
Displays real-time numerical values and graphical trends for flow and pressure, enabling quick identification of performance variations during testing.
Performs occlusion alarm verification and programmable back-pressure testing to ensure infusion pumps respond correctly under blocked-line conditions.
Measures bolus delivery volume, basal flow rate and PCA performance for comprehensive infusion pump verification.
Automatically stores test results and measurement data, providing complete traceability for preventive maintenance and compliance documentation.
Operate the Multi-Flo remotely from a PC using Med-eBase software, automate manufacturer-specific test routines and generate professional reports.
Routine testing and preventive maintenance of infusion and syringe pumps.
Verification of infusion pump performance during scheduled maintenance.
Portable field servicing and repair verification.
Production testing and quality assurance of infusion systems.
Calibration and verification of infusion devices.
Acceptance testing and commissioning of infusion pumps before clinical use.
Multi-channel testing enables engineers to verify up to four infusion pumps simultaneously, significantly reducing testing time.
Provides highly accurate flow, pressure and volume measurements for dependable verification of infusion device performance.
Supports manufacturer-specific automated test sequences through Med-eBase software, reducing manual intervention and human error.
Automatically stores test data and exports results for documentation, reporting and asset management.
Specification | Details |
Model | Rigel Multi-Flo |
Manufacturer | Rigel Medical |
Product Type | Infusion Pump Analyser |
Compliance | IEC 60601-2-24 |
Channel Options | 1, 2 or 4 Channels |
Flow Range | 0.010 – 1500 mL/h |
Measured Flow Range | 0.100 – 1450 mL/h |
Flow Accuracy | ±1% of Reading |
Pressure Range | -500 to 2500 mmHg |
Back Pressure | -200 to 600 mmHg |
PCA/Bolus Volume | 0.5 – 100 mL |
Total Volume | 0.001 – 9999 mL |
Display | ¼ VGA Colour Graphic LCD |
Communication | USB Type A & USB Type B |
Data Storage | Up to 360 Hours of Test Data |
Power Supply | 90–264 VAC, 50/60 Hz |
Weight | 5 kg (1 Channel), 6 kg (2 Channel), 8 kg (4 Channel) |
Protection Rating | IP40 |
Supplying genuine Rigel Medical products with manufacturer-backed warranty and technical support.
Expert assistance with installation, commissioning and biomedical application support.
Professional calibration, maintenance and after-sales support throughout West Africa.
Reliable delivery to hospitals, laboratories and healthcare facilities across the region.
The Multi-Flo is used to verify the performance of infusion pumps and syringe pumps by measuring flow rate, pressure, occlusion performance and bolus delivery in accordance with IEC 60601-2-24.
The Multi-Flo is available in 1, 2 and 4-channel configurations, allowing simultaneous testing of up to four infusion devices.
It accurately measures infusion flow rates from 0.010 to 1500 mL/h, making it suitable for both low-flow and high-flow infusion devices.
Yes. The Multi-Flo performs programmable occlusion and back-pressure testing, enabling verification of infusion pump alarm performance.
Yes. Using Med-eBase software, users can remotely control the Multi-Flo, automate test sequences and generate professional reports.
The Rigel Multi-Flo combines high-accuracy flow measurement, multi-channel testing, IEC 60601-2-24 compliance, automated test routines and comprehensive data management, making it an ideal solution for biomedical engineers responsible for infusion pump performance verification.
Fill out the form below to receive pricing, custom package configurations, or technical advice for Rigel Electrosurgery analyzers in West Africa.
Accra, Ghana
sales@aragonafrica.com