Rigel 62353+ Electrical Safety Analyser

The Rigel 62353+ Electrical Safety Analyser is a compact, battery-powered safety tester designed for fast and accurate testing of medical electrical equipment in accordance with IEC/EN 62353. Featuring automatic test sequences, onboard data storage, battery-powered insulation testing and flexible user-defined test routines, it provides biomedical engineers with an efficient solution for in-service and post-repair safety testing.


IEC/EN 62353 Testing
Battery Powered Operation
Automatic Test Sequences
Onboard Data Storage
Bluetooth / PC Communication
Earth Bond & Insulation Testing

BRAND

Rigel Medical

AVAILABILITY

In Stock

DELIVERY

West Africa

WARRANTY

Manufacturer Warranty

Compact & Rugged Design

The SafeTest 50 features a lightweight, durable design built for demanding hospital, laboratory and field service environments, making it ideal for routine biomedical safety inspections. 

International Safety Standards

Perform earth bond and insulation resistance testing without requiring mains power, allowing engineers to work safely and efficiently in busy clinical environments.

Flexible Test Sequences

Supports fully automatic, semi-automatic and manual testing with user-definable test routines to suit different maintenance procedures.

Onboard Data Storage

Store up to 10,000 test records, customised test sequences, visual inspections and performance tests for complete asset traceability.

Low Voltage Insulation Testing

Offers 50V, 100V, 250V and 500V DC insulation resistance testing, making it suitable for both conventional and low-voltage medical equipment.

PC Communication

Transfer stored test records directly to a PC using Med-eBase software for asset management, reporting and preventive maintenance scheduling.

Hospitals

Routine electrical safety testing of medical electrical equipment.

Biomedical Engineering Departments

Preventive maintenance and post-repair verification.

Medical Equipment Service Providers

Portable field testing during servicing and maintenance.

Calibration Laboratories

Verification of electrical safety according to international standards.

Medical Equipment Manufacturers

Production testing and quality assurance.

Healthcare Facilities

Acceptance testing and periodic compliance inspections.

Faster Testing

Automatic test routines reduce testing time while maintaining repeatable and reliable results. 

Complete Portability

Battery-powered operation eliminates trailing power cables, allowing unrestricted movement around medical equipment.

Accurate Results

Automatic secondary verification helps ensure correct measurements the first time, reducing repeat testing. (Medicalexpo)

Efficient Asset Management

Built-in memory and PC connectivity simplify test record management, reporting and preventive maintenance scheduling.

Specification

Details

Model

Rigel 62353+ Electrical Safety Analyser

Manufacturer

Rigel Medical

Standards

IEC/EN 62353, NFPA-99, AS/NZS 3551

Earth Bond Test

>200 mA DC

Insulation Voltage

50V, 100V, 250V & 500V DC

Leakage Current

Direct, Differential & Alternative

Power Measurement

0.1–4 kVA

Mains Outlet Test

0–300 VAC

Data Storage

Up to 10,000 Test Records

Test Modes

Automatic, Semi-Automatic & Manual

Connectivity

PC Communication (Med-eBase Compatible)

Battery

6 × AA Batteries

Weight

1.6 kg

Dimensions

270 × 110 × 75 mm

Why Choose Aragon Africa

Official Rigel Medical Distributor

Supply of genuine Rigel Medical products backed by manufacturer warranty.

Biomedical Expertise

Experienced engineers provide installation, commissioning and technical guidance.

Local Technical Support

Calibration, servicing and after-sales support across West Africa.

Fast Regional Delivery

Reliable logistics and prompt delivery to hospitals, laboratories and healthcare facilities.

Frequently Asked Questions

What is the Rigel 62353+ used for?

The Rigel 62353+ is designed for routine and post-repair electrical safety testing of medical electrical equipment in accordance with IEC/EN 62353.

It supports IEC/EN 62353, NFPA-99 and AS/NZS 3551 electrical safety testing standards.

Yes. It performs battery-powered earth bond and insulation resistance testing, allowing completely portable operation.

The analyser can store up to 10,000 test records, along with custom test routines and inspection data.

It supports insulation resistance testing at 50V, 100V, 250V and 500V DC, making it suitable for both standard and low-voltage medical equipment.

Yes. The Rigel 62353+ supports PC communication and works with Med-eBase software for downloading test records, managing assets and generating compliance reports.

Get In Touch

Request Electrosurgery Testing Quotation

Fill out the form below to receive pricing, custom package configurations, or technical advice for Rigel Electrosurgery analyzers in West Africa.

West Africa Hub

Accra, Ghana

Direct Sales Email