Comprehensive biomedical analyzers for infusion devices, syringe drivers, volumetric pumps, and PCA pumps with automated flow and occlusion testing per IEC 60601-2-24 standards.
Concurrent Channels
Compliant Testing
Flow Resolution
Automated Software
Delivering world-class Rigel Multi-Flo infusion pump analyzers designed for rapid, repeatable flow rate and occlusion verification.
Instantaneous flow rate measurement curves from 0.1 mL/hr up to 1500 mL/hr with high-accuracy optical displacement sensors.
Accurate peak pressure monitoring up to 30 PSI / 2000 mmHg to verify line blockage detection and safety alarm cut-offs.
Test up to 4 infusion channels simultaneously on a single analyzer to maximize biomedical lab throughput and efficiency.
In-house calibration, technical service, and repair facility in South Africa ensuring ongoing device accuracy and compliance.
High-accuracy multi-channel analyzers, specialized Luer-lock adapters, MED-eBase reporting software, and calibration service kits.
High-precision infusion pump analyzer with instantaneous flow measurement, occlusion pressure sensing, trumpet curve logging, and PCA bolus evaluation.
High-grade non-expansion medical tubing sets, priming fluid bags, male/female Luer-lock adapters, and waste drain collectors.
Automated database software for uploading test results, generating trumpet curves, scheduling routine PM, and printing compliance reports.
Annual ISO 17025 accredited calibration procedures, optical glass chamber cleaning, and sensor recertification for Multi-Flo units.
| CAPABILITY / SPECIFICATION | Multi-Flo (1 Ch) | Multi-Flo (2 Ch) | Multi-Flo (4 Ch) | MED-eBase Suite |
|---|---|---|---|---|
| Flow Rate Range (0.1 - 1500 mL/hr) | Data Logging | |||
| Occlusion Pressure (up to 30 PSI) | Graph Analysis | |||
| PCA Bolus Volume Measurement | Bolus Logs | |||
| Trumpet Curve Analysis | Auto Generator | |||
| Concurrent Channel Capacity | 1 Pump | 2 Pumps | 4 Pumps | Unlimited DB |
| IEC 60601-2-24 Protocol Automation | Built-in Templates |
Attach standard IV administration line or syringe to Multi-Flo Luer-lock inlet port with prime solution.
Choose flow rate test, PCA bolus volume check, or inline occlusion pressure limit sequence from menu.
Start pump delivery; optical displacement sensors record real-time instantaneous flow rate and cumulative volume.
Measure pressure rise time and peak occlusion pressure before pump safety cut-off alarm triggers.
Sync recorded data to MED-eBase software to generate trumpet curves and formal calibration certificates.
Verifies delivery rates down to 0.01 mL/hr for micro-infusion syringe pumps and high-volume infusion rates up to 1500 mL/hr.
Measures upstream and downstream line blockage threshold pressure to ensure patient safety against vein damage or line disconnects.
Captures Patient-Controlled Analgesia (PCA) bolus shot volumes, delivery speeds, and post-occlusion bolus release quantities.
Generates standardized trumpet curves showing short-term flow rate fluctuations and long-term delivery percentage errors per IEC 60601-2-24.
Specialized micro-flow detection ensures stable medication flow in neonatal care units and critical drug dosage environments.
Stores up to 24 hours of continuous flow curve data internally for subsequent download into hospital CMMS databases.
Routine preventive maintenance on critical care volumetric pumps and neonatal syringe drivers.
BMET technicians carrying out rapid, multi-pump batch testing across hospital wards.
Independent medical equipment service companies issuing annual flow calibration certificates.
End-of-line quality control testing during infusion pump manufacturing and assembly.
ISO 17025 accredited metrology laboratories requiring traceable volumetric standard devices.
Outfit your biomedical engineering teams with Rigel Multi-Flo analyzers for fast, repeatable infusion pump verification, automated trumpet curve logging, and complete IEC 60601-2-24 compliance.